Processing temperature |
-40... +150°C |
Maxsimum + 200°C |
|
Pressure range |
0/0,6 ... 0/600 bar |
|
Operating pressure (max.) |
A maximum of 75% of the Full Cipher Value must not exceed. |
|
Overpressure limit |
PN x 1,25 |
|
Sensitivity class |
KL 1,0 |
|
Relevance |
DIN / ANSI |
|
Optimum range of measurement |
0,1 PN ile 0,75 x PN between |
|
Protection class |
IP 41 |
|
Storage temperatures |
-40 ... +70°C |
|
Mechanical shock test load |
15 g |
|
Mechanical vibration test |
10 Hz ile 150 Hz - 1 oktav/dk.2s / 3 axis |